Quest for the right Drug
דטסקאן DATSCAN 74 MBQ/ML (IOFLUPANE)
תרופה במרשם
תרופה בסל
נרקוטיקה
ציטוטוקסיקה
צורת מתן:
תוך-ורידי : I.V
צורת מינון:
תמיסה להזרקה : SOLUTION FOR INJECTION
עלון לרופא
מינוניםPosology התוויות
Indications תופעות לוואי
Adverse reactions התוויות נגד
Contraindications אינטראקציות
Interactions מינון יתר
Overdose הריון/הנקה
Pregnancy & Lactation אוכלוסיות מיוחדות
Special populations תכונות פרמקולוגיות
Pharmacological properties מידע רוקחי
Pharmaceutical particulars אזהרת שימוש
Special Warning עלון לרופא
Physicians Leaflet
Posology : מינונים
4.2 Posology and method of administration Prior to administration appropriate resuscitation equipment should be available. DaTSCAN should only be used in adult patients referred by physicians experienced in the management of movement disorders and/or dementia. DaTSCAN should only be used by qualified personnel with the appropriate government authorisation for the use and manipulation of radionuclides within a designated clinical setting. Posology Clinical efficacy has been demonstrated across the range 111 to 185 MBq. Do not exceed 185 MBq and do not use when the activity is below 110 MBq. Patients must undergo appropriate thyroid blocking treatment prior to injection to minimise thyroid uptake of radioactive iodine, for example by oral administration of approximately 120 mg potassium iodide 1 to 4 hours prior to injection of DaTSCAN. 1 Special populations Renal and hepatic impairment Formal studies have not been carried out in patients with significant renal or hepatic impairment. No data are available (see section 4.4). Paediatric population The safety and efficacy of DaTSCAN in children aged 0 to 18 years has not been established. No data are available. Method of Administration For intravenous use. DaTSCAN should be used without dilution. To minimise the potential for pain at the injection site during administration, a slow intravenous injection (not less than 15 to 20 seconds) via an arm vein is recommended. Image acquisition SPECT imaging should take place between three and six hours post-injection. Images should be acquired using a gamma camera fitted with a high-resolution collimator and calibrated using the 159 keV photopeak and a ± 10% energy window. Angular sampling should preferably be not less than 120 views over 360 degrees. For high resolution collimators the radius of rotation should be consistent and set as small as possible (typically 11-15 cm). Experimental studies with a striatal phantom, suggest that optimal images are obtained with matrix size and zoom factors selected to give a pixel size of 3.5 – 4.5 mm for those systems currently in use. A minimum of 500k counts should be collected for optimal images.
שימוש לפי פנקס קופ''ח כללית 1994
לא צוין
תאריך הכללה מקורי בסל
לא צוין
הגבלות
לא צוין
מידע נוסף