Quest for the right Drug
כלוראפרפ עם גוון CHLORAPREP WITH TINT (CHLORHEXIDINE GLUCONATE, ISOPROPYL ALCOHOL)
תרופה במרשם
תרופה בסל
נרקוטיקה
ציטוטוקסיקה
צורת מתן:
חיצוני : EXTERNAL
צורת מינון:
אין פרטים : CUTANEOUS SOLUTION
עלון לרופא
מינוניםPosology התוויות
Indications תופעות לוואי
Adverse reactions התוויות נגד
Contraindications אינטראקציות
Interactions מינון יתר
Overdose הריון/הנקה
Pregnancy & Lactation אוכלוסיות מיוחדות
Special populations תכונות פרמקולוגיות
Pharmacological properties מידע רוקחי
Pharmaceutical particulars אזהרת שימוש
Special Warning עלון לרופא
Physicians Leaflet
Posology : מינונים
4.2 Posology and method of administration Posology ChloraPrep with Tint may be used on all age groups and patient populations. Paediatric population However, ChloraPrep with Tint should be used with care in newborn babies, especially those born prematurely (see also section 4.4, Special warnings and precautions for use). One applicator is used containing 3 ml, 10.5 ml or 26 ml of the ChloraPrep withTint alcoholic solution. Method of administration For cutaneous use The choice of applicator will depend on the invasive procedure being undertaken and the clinician’s preference. Applicator Coverage Area (cm x cm) For Procedures such as: 3 ml - Midline & Central Venous Catheter 15 X 15 (CVC) insertion and maintenance - Peritoneal dialysis site cleansing 10.5 ml - Minor and major surgical procedures - Implantable device placement 25 X 30 - Prosthetic device placement or removal - Midline, Peripheral Intravascular Central Catheter (PICC) & CVC 26 ml insertion and maintenance - Cardiac catheterisation and Cardiac 50 X 50 Cath Lab procedures - Interventional Radiology procedure The applicator is removed from the wrapper and held with the sponge facing downward. The applicator is squeezed gently to break the ampoule containing the antiseptic solution, which is released onto the sponge in a controlled flow (for the 26 ml applicator the lever is pressed). Pinch wings once only to activate the applicator and release the antiseptic. Do not repeatedly pinch or pump the wings in an attempt to accelerate the saturation of the foam. The broken ampoule remains safely contained within the applicator. The sponge is gently pressed against the patient’s skin in order to apply the antiseptic solution. Once the solution is visible on the skin, use gentle back and forth strokes to prep the site for 30 seconds. The 26 ml applicator includes two swabs. Clean intact umbilicus with enclosed swabs when applicable. (Moisten swabs by pressing against solution-soaked sponge applicator.) The area covered should be allowed to air dry completely. It is recommended that ChloraPrep with Tint remain on the skin post-procedure to provide continued antimicrobial activity. The tint will slowly fade from the skin. If removal is necessary, remove with soap and water or alcohol.
שימוש לפי פנקס קופ''ח כללית 1994
לא צוין
תאריך הכללה מקורי בסל
לא צוין
הגבלות
לא צוין
רישום
172 48 36417 00
מחיר
0 ₪
מידע נוסף